of 5
Next
View
Belden 29526C 0105000 VFD, 3C #4 Str BC XLPO Ins + #6 Symm. Seg. Gnd (3 of #12) Str BC, CTS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Shielding: Corrugated or Helical Tape(s)
- Stranding Material: Bare Copper - Stranded
- Product Category: Basics VFD
- Insulation Description: XLPE - Cross Linked Polyethylene
Belden 29504F 0101000 VFD 300% Gnd, 3C+IG #8 Str TC, XLPO Ins+PVC Gnd, OS+TC Brd, Blk TPE Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable
- Conductor Material: Tinned Copper
- Product Category: High Flex VFD
- Shielding: Foil + Braid(s)
- Insulation Description: PVC - Polyvinyl Chloride
- Stranding Material: Tinned Copper - Stranded
Belden 29729C 0103000 VFD, 3C #1/0 Str BC XLPO Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Stranding Material: Bare Copper - Stranded
- Insulation Description: XLPE - Cross Linked Polyethylene
- Product Category: Basics VFD - 2000V
- Shielding: Corrugated or Helical Tape(s)
Belden 29529C 0102000 VFD, 3C #1/0 Str BC XLPO Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Shielding: Corrugated or Helical Tape(s)
- Stranding Material: Bare Copper - Stranded
- Product Category: Basics VFD
- Insulation Description: XLPE - Cross Linked Polyethylene
Belden 29732C 0102000 VFD, 3C #4/0 Str BC XLPO Ins + #3 Symm. Seg. Gnd (3 of #8) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Insulation Description: XLPE - Cross Linked Polyethylene
- Shielding: Corrugated or Helical Tape(s)
- Stranding Material: Bare Copper - Stranded
- Product Category: Basics VFD - 2000V
Belden 29532 0102000 VFD 100% Gnd, 3C #4/0 Str TC XLPE Ins + #4/0 Symm. Seg. Gnd (3 of #2) Str BC, CTS, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
- Conductor Material: Tinned Copper
- Stranding Material: Tinned Copper - Stranded
- Shielding: Corrugated or Helical Tape(s)
- Product Category: Premium VFD
- Insulation Description: XLPE - Cross-Linked Polyethylene (Thermoset)
Belden 29529 0102000 VFD 100% Gnd, 3C #1/0 Str TC XLPO Ins + #1/0 Symm. Seg. Gnd (3 of #4) Str BC, CTS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable
- Conductor Material: Tinned Copper
- Insulation Description: XLPE - Cross Linked Polyethylene
- Shielding: Corrugated or Helical Tape(s)
- Product Category: Premium VFD
- Stranding Material: Tinned Copper - Stranded
Belden 29524C 0105000 VFD, 3C #8 Str BC XLPO Ins + #10 Symm. Seg. Gnd (3 of #14) Str BC, CTS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Stranding Material: Bare Copper - Stranded
- Product Category: Basics VFD
- Shielding: Corrugated or Helical Tape(s)
- Insulation Description: XLPE - Cross Linked Polyethylene
Belden 29730C 0102500 VFD, 3C #2/0 Str BC XLPO Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Product Category: Basics VFD - 2000V
- Shielding: Corrugated or Helical Tape(s)
- Insulation Description: XLPE - Cross Linked Polyethylene
- Stranding Material: Bare Copper - Stranded
Belden 29731C 0102500 VFD, 3C #3/0 Str BC XLPO Ins + #3 Symm. Seg. Gnd (3 of #8) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Shielding: Corrugated or Helical Tape(s)
- Stranding Material: Bare Copper - Stranded
- Product Category: Basics VFD - 2000V
- Insulation Description: XLPE - Cross Linked Polyethylene
Belden 29722C 0105000 VFD, 3C #12 Str BC XLPO Ins + #12 Symm. Seg. Gnd (3 of #16) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Insulation Description: XLPE - Cross Linked Polyethylene
- Shielding: Corrugated or Helical Tape(s)
- Product Category: Basics VFD - 2000V
- Stranding Material: Bare Copper - Stranded
Belden 29506 0103000 VFD 300% Gnd, 3C+IG #4 Str TC, XLPO Ins+PVC Gnd, OS+TC Brd, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable
- Conductor Material: Tinned Copper
- Stranding Material: Tinned Copper - Stranded
- Product Category: Premium VFD
- Shielding: Foil + Braid(s)
- Insulation Description: XLPE - Cross Linked Polyethylene